Landmark, Gas/Electric Packaged Unit, 3 Ton, Standard Efficiency, 65,000 Btuh, Direct Drive-CAV Blower, 208-230V, 1 Phase, 60 Hz, KGB036S4DW

Cat # : AC298

Model/Part # : KGB036S4DW

Quantity:

Save to List


Brand
Lennox
Catalog Number
AC298
Model/Part Number
KGB036S4DW
Minimum Order Quantity
0.0
Base Unit of Measure
Unit(S)
EAN / UPC
66255148744
Product Voltage
208/230v 1ph 60 hz
Horsepower
0.5
SEER
14
Heat
65 Single
Return Opening Horizontal
11 X 29
Return Opening Downflow
11 X 29
Tonnage
3
Supply Opening Horizontal
19.5 x 20
Supply Opening Downflow
18 X 20
Gross Weight
596 LB
Family
KGB
Cooling Capacity
3.0 Ton Cooling
Heating Capacity
65, 000 Btuh
Efficiency
14.0 SEER
Package Unit Cabinet
A Cabinet
Package Unit Type
Gas Package Unit
Package Unit Tonnage
3.0
Package Unit Efficiency
Standard Efficiency
Unit Refrigerant
R-410A
Unit Cabinet Height
Short (34" Coil)
Unit Orientation
Downflow
Voltage
208-230 Volt/1 Ph
Air Filter Type
2" MERV4 - Std Filter
Unit Blower Type
Constant Volume Direct Drive
Blower Motor
.5 Hp Direct Drive
Gas Heating
65K A.S. (Single Stage)
Coil System
Environ Coil System
Low NOx Emission
Factory Installed
Stuttgart Capacity Line
L08

Product Overview

KGB036S4D

Landmark® Rooftop Units Standard Efficiency 2-7.5 tons

Packaged Gas/Electric 60 hz and 50 hz

Performance Marked by Flexibility

Efficiency

  • New 7.5 to 25-ton high-efficiency units (gas/electric and electric/electric)
  • Up to 13.0 SEER, 14.5 IEER and 12.7 EER
  • 2 to 25 tons (gas/electric and electric/electric)
  • 2 to 20 tons (heat pump)
  • Meet or exceed ASHRAE 90.1-2004 standards
  • Available MSAV® supply fan provides year-round savings and comfort with reduced energy consumption, improved indoor air quality and code compliance
  • Up to 61% supply fan savings with optional MSAV
  • Direct-spark ignition enhances efficiency

Serviceability

  • Isolated compressor compartment allows performance check during normal compressor operation without disrupting airflow
  • Slide-out blower allows quick belt tensioning, adjustment or replacement and makes cleaning the blower easier
  • Accessible gas compartment provides generous space to access all gas components, making analysis and service easier
  • Optional hinged access panels provide quick access to components and protect panels and roof from damage during servicing
  • Full-perimeter base rail provides greater structural integrity, so the unit is easier to handle when rigging and transporting
  • Fork slots on three sides make it easy to pick up and transport units from almost any angle
  • Independent motor mount allows for easy and efficient service access without removing the top panel
  • Environ™ Coil System on 7.5 to 25-ton standard and high-efficiency gas/electric and electric/electric units reduces the time necessary to clean the condensing coil

Reliability

  • Landmark units with the most popular features and configurations are stocked and ready for fast delivery or pickup at commercial depots across North America
  • Pre-defined supply fan motor/drive combinations make selecting components to meet static and airflow requirements quick and easy
  • Thermostatic expansion valves on high-efficiency models and fixed orifice on standard-efficiency models
  • Environ™ Coil System provides reliable operation in a wide range of applications
  • Scroll compressor provides reliable, long-term operation
  • Interlink compressor delivers increased reliability and better efficiency

Comfort/IAQ

  • Corrosion-resistant, removable, double-sloped drain pan provides application flexibility, durability and improved serviceability
  • First stage operation of the optional MSAV® supply fan reduces humidity, providing better space comfort
  • Field or factory-installed MERV 8 or 13 filters reduce airborne particles
  • Field-installed CO2 sensors reduce levels of CO2 and VOCs by introducing fresh outside air

Options

Field-installed accessories

  • Field powered GFI
  • Disconnects
  • Economizers with single or dual enthalpy control
  • Electric heat
  • 50% constant volume powered exhaust fan
  • CO2 sensor
  • Return and supply air smoke detectors
  • Low ambient kits
  • Hail guards
  • Coil guards
  • Link to the L Connection® Network line of commercial controls with an optional Network Thermostat Controller
  • LPG Conversion Kit (gas/electric only)
  • -40°F cold weather kit (gas/electric only)
  • Combustion air intake or flue exhaust extensions (gas/electric only)
  • Blower proving switch
  • Dirty filter switch
  • Manual outdoor air dampers (25%)
  • Motorized outdoor air dampers

Factory-installed options

  • MSAV (multi-stage air volume) supply fan
  • Coil corrosion protection
  • Stainless steel heat exchanger
  • Hinged doors

Factory options or field accessories

  • Economizer (Standard and Title 24 High Efficiency)
  • Barometric relief dampers
  • High and low-static drive kits
  • Heaters (electric/electric only)
  • BACnet module
  • Novar 2051 ETM module